Indonesia
English

Series AP directly operated proportional valves



Download PDF (1.192,3 Kb

2/2-way proportional valves, NC
Sizes: 16 - 22 mm

General Data:

Function 2/2 NC
Operation proportional directly operated
Ports M5 - G1/8
Nominal diameter (ø) see table
Nominal flow (Qn - Kv) see table
Maximum operating pressure see table
Hysteresis 16 mm size < 7% 22 mm size < 5%
Repeatability 16 mm size < 5% 22 mm size < 3%
Operating temperature 0 ÷ 60°C
Medium filtered compressed air, unlubricated, according to ISO 8573-1 class 3.4.3, inert gas
Installation in any position
Materials body = brass / PVDF (for size 16mm only)
seals = NBR

Nominal resistance
Related current
GP7            GPH          U711         U712
193 ohm    48 ohm     85 ohm      22 ohm
125 mA      250 mA    271 mA       0.542 mA
   
While choosing the valve characteristics and in order to reach the highest performances, it is important to know that there must be a pressure difference of 90% at least between the inlet and the outlet. For example: inlet P 10 bar - outlet P max 1 bar up to free flow.
   
CODE:

AP - 7 2 1 1 - L R 2 - G 7 11
AP SERIES
7 BODY:
6 = Size 16 mm
7 = Size 22 mm
2 NUMBER OF WAYS:
2 = 2-way
1 VALVE FUNCTION:
1 = NC
1 PORTS:
0 = M5 (for size 16 mm only)
1 = G1/8 (for size 22 mm only)
L = barbed fittings (for body in PVDF only, size 16 mm)
L NOMINAL DIAMETER:
D = ø 0.8 mm (for size 16 mm only)
F = ø 1 mm
H = ø 1.2 mm
L = ø 1.6 mm
N = ø 2 mm (for size 22 mm only)
Q = ø 2.4 mm (for size 22 mm only)
R SEALS MATERIAL:
R =NBR
2 BODY MATERIAL:
2 = brass
3 = PVDF (for size 16 mm only)
G ENCAPSULATING MATERIAL:
G = PA (for size 16 mm only) U = PET (for size 22 mm only)
7 SOLENOID DIMENSIONS:
P = 16x26 DIN EN 175301-803-C (for size 16 mm only)
7 = 22x22 DIN 43650 B (for size 22 mm only)
11 SOLENOID VOLTAGE:
H = 12 V DC 3 W (for size 16 mm only)       7 = 24 V DC 3 W (for size 16 mm only)