Indonesia
English

Valves and Solenoid valves Series 9



Download PDF (1.133,8 Kb

5/2 and 5/3 way C.C. C.O. Sizes 1 - 2 - 3 According to the standard ISO 5599/1

Series general data


Operating pressure max. press. 10 bar (for minimum pressures see descriptions)
Nominal pressure 6 bar
Nominal flow ISO 1= 900 Nl/min ISO 2 = 1610 Nl/min ISO 3 = 4350 Nl/min
Operating temperature 0 ÷ 60°C (with dry air at -20°C)
Fluid filtered air, without lubrication. If lubricated air is used, it is recommended to use ISOVG32 oil and to never interrupt the lubrication.
Interface electropneumatic CNOMO Standards

Code

9 5 1 - C 1 B - P16 - 23 - U 7 7

 


9
SERIES
5
NO OF WAYS/POSITIONS:
5 = 5/2
6 = 5/3 Closed Centres
7 = 5/3 Open Centres
1
SIZE:
1 = size 1
2 = size 2
3 = size 3
C
SUB-BASE:
C = ISO (manifold outlets)
F = ISO (single sub-base, side ports)
G = ISO (single sub-base, rear ports)
N = ISO (front outlet interface)
N1A = (front outlet sub - base ) 
1
PORTS (OUTLETS):
Size 1 = G1/4
Size 2 = G3/8
Size 3 = G1/2  
B
N° OF SUB-BASE:
A = 1
*B = 2
*C = 3
*D = 4
*E = 5
*F = 6
*G = 7
*H = 8
*K = 9
*L = 10
*M= 11
*N = 12
*P = 13
*R = 14
*S = 15
P 16
ACTUATION:
33 = pneumatic, pneumatic return
34 = pneumatic, differential pneumatic return
35 = pneumatic, mechanical spring return
P11 = double solenoid (horizontal solenoids)
P15 = single solenoid, spring return (horizontal solenoids)
P16 = solenoid, pneumatic spring return (horizontal solenoids)  
23
SOLENOID INTERFACE:
23 = A531 - BC2
U
SOLENOID MATERIAL:
U = PET
G = PA
A8 = PPS
H8 = PA 6 VO 
7
SOLENOID DIMENSIONS:
7 = 22 x 22
8 = 30 x 30
9 = 22 x 58
7
SOLENOID VOLTAGE:
See solenoids page 2.2.35.01